Apex Digital apex 10 Servisní příručka Strana 89

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 134
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 88
APEX — Installation and Service Manual 91
Reference Connections
Single AES Reference
Since there is only one AES reference in this example shown in Figure 38, it
must be selected for use by all input and output boards. On systems with
the CX-34000 Control Crosspoint boards (all present systems), this selection
is made with DIP switches marked REF; all these switches would be set to
binary 1. For the location of these switches, see
Figure 41 on page 98.
Figure 38. Single AES Reference
AES REF A
VID REF A
House AES reference A
Input and output
board(s) on
AES Ref A
1
Binary ID used for assigning
reference to input and output board
with XPT board DIP switches